SNG(Shinko Web Guide System)is an auto-positioning system for the edges, lines and centers of a web.This system can greatly contribute to saving labors, resources and production costs, increasing prodctivity and product quality.
|
 |
Hydraulic Web Guide System |
 |
WINDER GUIDE |
 |
 |
Air sensor detect the edge position of the material which runs a process line and receive the signal at power unit side.
The system of composition are hydraulic pump and air pump (source for detectors of air), which attached air regulator and servo valve assembly.
|
■ Air Detector |
■ Power Unit |
 |
 |
An oil flow is replaced in proportion to a deviation signal by the servo valve on power unit, a guide mechanism is operated, and correction control of the run position of material
at normal position.
In case of need, We can supply the explosion-proof and .increased safety type explosion-proof.
|
CENTER GUIDE |
 |
REWINDER GUIDE |
Power Unit Specification: |
Air detector Pneumatic-Hyd. System |
|
J-25 |
J-50 |
Power unit |
Moter |
400W
0.78MPa {8kgf/cm2}
4.5ℓ/min |
400W
1.27MPa {13kgf/cm2}
9.0ℓ/min |
Hyd press |
Oil Flow |
Tank capacity |
12.3ℓ |
Air Pump |
50ℓ/min |
LP ( Standard)
HP ( High pressure) Plant air type |
2.2kPa {9 INH2O}
3.73kPa
|
Detector |
Twin flow air type detector ( Air pressure 1.23~2.45kPa) |
Performance |
Max. Thrust
Max. Speed ( No Load)
Accuracy of detector |
1.4kN { 140kgf (φ50cyl) }
27mm/sec(φ50)
0.05mm |
6.1kN { 625kgf (φ80cyl) }
21mm/sec(φ80)
0.05mm |
※Rated capacity |
|
400W |
400W |
200V |
400V |
200V |
400V |
Breaker |
5A |
3A |
5A |
3A |
Thermal |
1.8A |
0.9A |
1.8A |
0.9A |
 |
※It show reference data |
|
|
 |